blogThe connection method of 6-core 10 Gigabit OM3 and OM4 fibers mainly involves the selection of fiber patch cables, the type of connectors and the connection method. The following is a detailed answer to these aspects:
First, the choice of fiber optic jumpers
Matching the number of cores: Since the requirement is to connect a 6-core fiber, a 6-core fiber patch cable needs to be selected.
Type selection: OM3 and OM4 fibers differ slightly in tranSMission performance, but they are physically compatible. Therefore, a jumper cable suitable for OM3 or OM4 fibers can be selected. However, to ensure optimum performance, it is recommended to choose a jumper that matches the fiber type.
Length Consideration: Choose the appropriate jumper length according to the application requirements. In applications such as data centers, shorter jumpers are usually selected to reduce signal attenuation and interference.
Second, the type of connector
LC connector: LC connector is one of the commonly used connector types in data centers and optical networks. It has the advantages of small size, easy pluggability and high density. OM3 and OM4 fibers are usually connected using LC connectors.
MTP/MPO connectors: For high-density connection scenarios, MTP/MPO connectors are a better choice. They can support up to 12-core or 24-core fiber optic connections, and have higher connection densities and fewer connection points, thus reducing signal attenuation and interference.
III. Connection method
Pre-terminated fiber optic jumpers: Using pre-terminated fiber optic jumpers simplifies the connection process. These jumpers have been terminated and tested at the factory, so users simply plug the connector of the jumper into the corresponding port.
Field termination: If you need to use the field termination method, you need to prepare the necessary tools and materials such as fiber stripping pliers, fiber cutting knives, fiber cleaning tools, and fiber welding machines. Then follow these steps:
Peel off the outer skin and coating of the optical fiber to expose the optical fiber core.
Use a fiber cutter to cut the fiber end face flat.
Clean the fiber optic end faces to ensure there is no dust or contaminants.
Put the optical fiber into the welding machine for welding.
Use a heat shrinkable sleeve to protect the fusion joint and heat it to shrink to fix it.
Install the connector to the optical fiber and ensure that it is firmly fixed.
IV. Precautions
Cleanliness: During the connection process, it is crucial to maintain the cleanliness of the fiber optics and connectors. Any dust or contaminants can cause connection failure or performance degradation.
Matching: Ensure that the selected fiber optic jumpers and connectors are compatible with OM3 or OM4 fibers.
Performance testing: After the connection is completed, performance testing is recommended to ensure the quality and reliability of the connection.
In summary, the connection of 6-core 10 Gigabit OM3 to OM4 fiber requires selecting the appropriate jumper, connector type, and the correct connection method. At the same time, pay attention to maintaining cleanliness and matching, and conduct performance tests after the connection is completed.